Upgrades & Modifications · Motogadget m.unit blue — solid-state loom architecture
I/O
Value
12 inputs · 10 outputs
Applies · any 12 V rewire
Outputs (+12 V): L & R signals, Lo, Hi, starter, horn, brake, ignition, AUX1, AUX2. Inputs: 1× +12 V switched (ignition lock or m.lock) + 11× ground-switched pilots incl. kill, kickstand, LIN-bus. Voltage window differs by generation: the current mo.unit blue/basic manual (V3.1) specifies 9–15 V, 12 V systems only, and warns that reverse polarity or anything above 15 V may damage the unit. The earlier m.unit blue/basic manual (V2.3) quoted 6–18 V. Neither generation is a 6–20 V device — check the manual revision that shipped with your serial number.
This is the book's general row. In the book, pick your model and year and this figure resolves to your machine, with the one-page torque sheet, the job pages and the printable booklet.
Open in the bookReport an error in this figure
Also in Motogadget m.unit blue — solid-state loom architecture