Airhead Reference › The book › Upgrades & Modifications › Power feed & ground
Upgrades & Modifications · Motogadget m.unit blue — solid-state loom architecture

Power feed & ground

▲ Safety-critical — over-torque-intolerant. Do not exceed the figure.
Value
10 mm² (7 ga) battery cable, M5 terminal
Applies · install
The unit earths through its two M5 mounting screws, and motogadget requires that one of those screws be run directly to the battery minus terminal — not merely to a clean chassis point. Both the V2.3 and V3.1 manuals state this in the same words. Chassis metal alone is not the specified path: a powder-coated bracket is an open circuit, and even bare steel through an airhead frame gives you a resistance you did not design for. Motogadget's stated minimum supply cable is 6 mm²; 10 mm² is the comfortable choice. Main supply fuse 40 A maximum.

This is the book's general row. In the book, pick your model and year and this figure resolves to your machine, with the one-page torque sheet, the job pages and the printable booklet.

Open in the book
Report an error in this figure

If this figure disagrees with your manual, say which manual and which page. Every report is checked against the source before anything in the book changes.

Also in Motogadget m.unit blue — solid-state loom architecture